STEAM INJECTION
-
Brand:ADCA
Description
The SI20 series steam injectors from ADCA are injection
condensers. They ensure low noise and vibration and
rapid heating of still or flowing fluids in basins and
vessels due to direct steam injection.
Steam enters through the inlet housing, passes along the
centre of the heater, through holes in the inner rings,
through spaces between the element plates where it
condensates under light load and partly condensates
under heavy load to be discharged through the serrated
periphery of the element plates. Under heavy load if any
steam pass through the periphery of the element plates,
will do so in very small jets and will condensate in the
surrounding liquid with very little noise and vibration.
Connections are female screwed.
MAIN FEATURES
Quiet operation.
Corrosion-resistant.
No moving parts.
OPTIONS:
Complete system including vacuum
breaker and self operated controller.
Different capacities and design available
under request.
USE:
Direct steam injection heating systems.
See IMI installation and maintenance
instructions.
AVAILABLE
MODELS:
SI 20-4; SI 20-5,5; SI 20-7; SI 20-8,5
SIZES: 3/4"
CONNECTIONS: Female screwed ISO 7/1 Rp (BS21)
INSTALLATION: Horizontal or vertical installation.
LIMITING CONDITIONS:
PMO: Max. operating pressure 8,5 bar
TMO: Max. operating temperature 180 ºC