SANITARY PRESSURE REDUCING VALVE P-130C (Clamped body)

  • Brand:
    ADCA

Description

DESCRIPTION

The ADCA P-130C series direct acting, spring-loaded
diaphragm sensing , pressure reducing valves are
designed for use on compressed air, water and other
gases or liquids compatible with the materials of
construction .

MAIN FEATURES

Compact design.
Completely machined from barstock material, no
castings or forgings are used on the standard version.
No rising stem

STANDARD SURFACE FINISH
Internal wetted parts: ≤ 0,5 micron Ra
External : ≤ 0,8 micron Ra
( 0,25 micron Ra and electro polished as option)
Ultrasonic cleaning

OPTIONS: Self relieving

Leakage line connection 1/8” (captured vent). 

Gauge connection on body
Different soft valves for liquids and gases.
Special execution for steam.


USE: Compressed air, water and other gases and
liquids compatible with the construction.

AVAILABLE MODELS: P-130C

SIZES: DN1/2” to DN 1” ; DN15 to DN25

OUTLET SPRING
RANGES: 0,2 – 1,5 bar; 0,3 – 3 bar; 0,8 – 8 bar.


CONNECTIONS: Clamp ends or others on request

PACKAGING:
Assembling and packaging in a clean room
certified according to ISO 14644-1.
The product is end capped and vacuum sealed
with recyclable plastic film to avoid
contamination.


INSTALLATION: Horizontal installation.

ORDER
REQUIREMENTS:
Type of fluid
Maximum operating temperature
Inlet pressure and required outlet pressure
Capacity (maximum and minimum).